Dual fuel generator set is an innovative technology that can use a mixture of diesel and natural gas as fuel, or operate solely on diesel in the absence of natural gas. It has the excellent and reliable performance of diesel engines, as well as the economic and environmental advantages of natural gas engines. When the load of the unit does not reach 30%, the unit is completely driven by diesel. As the load continues to increase, natural gas begins to be injected and mixed with diesel for combustion. As the load increases, the amount of natural gas input will correspondingly increase.
● Gas fuels suitable for dual fuel systems: pipeline natural gas PNG, liquefied natural gas LNG, compressed natural gas CNG, oilfield associated gas, biogas, coalbed methane, etc.
When the load of the unit does not reach 30%, the unit is completely driven by diesel. As the load continues to increase, natural gas begins to be injected and mixed with diesel for combustion. As the load increases, the amount of natural gas input will correspondingly increase.
1. The power of the unit remains basically unchanged
2. High emission level
3. Long term stable and safe operation
4. Low operating costs and high economic benefits
5. Natural gas has no carbon deposition
6. No particle generation
7. Reduce wear on cylinder liners and piston rings
8. Adapt to unstable gas supply and automatically switch between diesel mode/dual fuel mode
Advantages of Taifa Service: Establishing a 24-hour comprehensive service hotline, ready to provide services to customers at any time. Upon receiving a customer repair report, complete the dispatch work within 1 hour and provide feedback on the dispatch status to the customer at any time. Time sensitive service, available within 4 hours within the city, 6 hours within 100 kilometers, and 12 hours outside of 100 kilometers. Upon arrival at the scene, repair time is required. Generally, faults are repaired within 24 hours, while other faults are repaired within 72 hours.
| Model | Unit power | Fuel consumption rate g/kw·h | Gas consumption rate m³/KW·h | Oil and gas consumption ratio % | Length * Width * Height mm | Weight KG | Frequency HZ | |
| KW | KVA | |||||||
TFDG10 | 10 | 12.5 | ≤230 | 0.28 | 30%oil/70%gas | 1100*700*970 | 211 | 50/60 |
| TFDG15 | 15 | 18.75 | ≤230 | 0.28 | 30%oil/70%gas | 1600*680*1000 | 650 | 50/60 |
| TFDG20 | 20 | 25 | ≤230 | 0.28 | 30%oil/70%gas | 1600*680*1000 | 680 | 50/60 |
| TFDG30 | 30 | 37.5 | ≤230 | 0.28 | 30%oil/70%gas | 1800*750*1300 | 760 | 50/60 |
| TFDG40 | 40 | 50 | ≤230 | 0.28 | 30%oil/70%gas | 1800*750*1300 | 780 | 50/60 |
| TFDG50 | 50 | 62.5 | ≤230 | 0.28 | 30%oil/70%gas | 2350*730*1500 | 1100 | 50/60 |
| TFDG75 | 75 | 93.75 | ≤230 | 0.28 | 30%oil/70%gas | 2500*730*1500 | 1500 | 50/60 |
| TFDG100 | 100 | 125 | ≤230 | 0.28 | 30%oil/70%gas | 3000*1000*1700 | 1800 | 50/60 |
| TFDG120 | 120 | 150 | ≤230 | 0.28 | 30%oil/70%gas | 3000*1000*1700 | 1800 | 50/60 |
| TFDG150 | 150 | 187.5 | ≤230 | 0.28 | 30%oil/70%gas | 3100*1100*1700 | 2200 | 50/60 |
| TFDG180 | 180 | 225 | ≤230 | 0.28 | 30%oil/70%gas | 3100*1100*1700 | 2300 | 50/60 |
| TFDG200 | 200 | 250 | ≤230 | 0.28 | 30%oil/70%gas | 3200*1200*1800 | 2500 | 50/60 |
| TFDG250 | 250 | 312.5 | ≤230 | 0.28 | 30%oil/70%gas | 3500*1750*1980 | 3500 | 50/60 |
| TFDG300 | 300 | 375 | ≤230 | 0.28 | 30%oil/70%gas | 3500*1750*1980 | 3500 | 50/60 |
| TFDG350 | 350 | 437.5 | ≤230 | 0.28 | 30%oil/70%gas | 3500*1620*2000 | 3800 | 50/60 |
| TFDG400 | 400 | 500 | ≤230 | 0.28 | 30%oil/70%gas | 3600*1800*2150 | 4200 | 50/60 |
| TFDG450 | 450 | 562.5 | ≤230 | 0.28 | 30%oil/70%gas | 4400*1700*2200 | 6800 | 50/60 |
| TFDG500 | 500 | 625 | ≤230 | 0.28 | 30%oil/70%gas | 4500*1800*2250 | 7500 | 50/60 |
| TFDG550 | 550 | 687.5 | ≤230 | 0.28 | 30%oil/70%gas | 4600*1630*2250 | 7500 | 50/60 |
| TFDG600 | 600 | 750 | ≤230 | 0.28 | 30%oil/70%gas | 4900*2100*2500 | 8000 | 50/60 |
| TFDG650 | 650 | 812.5 | ≤230 | 0.28 | 30%oil/70%gas | 4900*2100*2500 | 8100 | 50/60 |
| TFDG700 | 700 | 875 | ≤230 | 0.28 | 30%oil/70%gas | 4900*2100*2500 | 8200 | 50/60 |
| TFDG800 | 800 | 1000 | ≤230 | 0.28 | 30%oil/70%gas | 5450*2200*2520 | 10200 | 50/60 |
| TFDG900 | 900 | 1125 | ≤230 | 0.28 | 30%oil/70%gas | 5450*2200*2520 | 11000 | 50/60 |
| TFDG1000 | 1000 | 1250 | ≤230 | 0.28 | 30%oil/70%gas | 5450*2200*2520 | 11500 | 50/60 |
| TFDG1200 | 1200 | 1500 | ≤230 | 0.28 | 30%oil/70%gas | 8600*2870*3000 | 20000 | 50/60 |
| TFDG1500 | 1500 | 1875 | ≤230 | 0.28 | 30%oil/70%gas | 8700*2980*3000 | 18000 | 50/60 |
| TFDG1800 | 1800 | 2250 | ≤230 | 0.28 | 30%oil/70%gas | 9600*2870*3000 | 21200 | 50/60 |
| TFDG2000 | 2000 | 2500 | ≤230 | 0.28 | 30%oil/70%gas | 9600*2870*3000 | 21500 | 50/60 |
| TFDG2500 | 2500 | 3750 | ≤230 | 0.28 | 30%oil/70%gas | 9200*2300*3500 | 48000 | 50/60 |
| TFDG3000 | 3000 | 3750 | ≤230 | 0.28 | 30%oil/70%gas | 9200*2300*3500 | 49000 | 50/60 |
Standard unit 50HZ, 230/400V, power factor 0.8, three-phase four wire system. 60Hz and high-voltage units can be customized according to customer requirements.
Optional options include soundproof speakers, shipping containers, and waste heat recovery systems.
The interpretation rights of this type of music chart belong to Taifa New Energy, and any changes may be made without prior notice.
If you need specific model parameters and related technical solutions for dual fuel generator sets, please contact us by phone at 135 1515 5003 (same WeChat number)
微信扫码,添加客服
24小时咨询热线0523-80630566
移动电话13515155003
Copyright © Taizhou Taifa New Energy Technology Co., Ltd All Rights Reserved. 地址:599 Xiangtai Road, Taizhou City, Jiangsu Province XML地图